CONSTANT VOLTAGE OPERATION | Regulation | Line regulation < 0.01% + 3mV Load regulation : < 0.01% + 5mV (rating current <10A < 0.02% + 5mV (rating current > 10A) |
| Ripple & Noise | < 1mVrms 5Hz ~ 1MHz |
| Recovery Time | < 100µS (50% Load change, Minimum load 0.5A) |
|
CONSTANT CURRENT OPERATION | Regulation | Line regulation < 0.2% + 3mA Load regulation < 0.2% + 3mA |
| Ripple Current | < 3mA rms(<10A), < 5mA rms(<20A), < 20mA rms(<50A) |
|
| METER | Digital | 3 1/2 digits 0.5" LED display (x2) Accuracy + (0.5% of rdg + 2 digits) |
|
INSULATION GPR-1810HD GPR-3060D, GPR-3060D | Chassis & Terminal | 20MΩ or above ( DC 500V ) |
| Chassis & AC Cord | 30MΩ or above ( DC 500V ) |
|
INSULATION All Others | Chassis &Terminal | 100MΩ or above ( DC 1000V ) |
| Chassis & AC Cord | 100MΩ or above ( DC 1000V ) |
|
| POWER SOURCE | AC 100V/120V/220V/240V +10%, 50/60Hz |
|
| ACCESSORIES | Instruction manual x 1, Power cord x 1 Test lead GTL-105 x 1 (<3A) or GTL-104A x 1 (<10A) Not supplied on units >10A |
|
| DIMENSIONS | 255(W) x 145(H) x 420(D) mm |
|
| WEIGHT | GPR-1810HD, GPR-3060D, GPR-6030D 29 lbs. GPR-11H30D, GPR-30H10D 33 lbs. All Others 39 lbs |